Lachman · Part I · Chapter 3

Drying

Moisture terms, the drying rate curve, and the main dryers from tray and fluid-bed to spray dryers and freeze dryers.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Theory

  • Moisture content can be expressed on a wet basis (% of wet weight) or a dry basis (% of dry solid weight); loss on drying (LOD) uses wet basis.
  • Equilibrium moisture content is the moisture a solid holds at a given humidity; free moisture is the amount above it that can be removed.
  • The drying rate curve has an initial adjustment, a constant-rate period (surface evaporation, like a free water surface) and a falling-rate period (internal diffusion controls).
  • The critical moisture content marks the change from constant to falling rate.
  • Migration of soluble drug or dye to the surface of granules during tray drying causes mottling and uneven content.

Dryers

  • Tray (static bed) dryers are simple but slow and give migration; fluid-bed dryers suspend granules in hot air for fast, uniform drying.
  • Spray dryers atomise a solution or suspension into hot gas and give spherical, free-flowing particles in seconds; used for heat-sensitive materials because the droplets stay cool while water evaporates.
  • Vacuum dryers lower the boiling point for heat-sensitive or solvent-wet materials.
  • Freeze drying (lyophilisation) freezes the product, then removes ice by sublimation (primary drying) and bound water by desorption (secondary drying); used for proteins, vaccines and unstable injections.
  • Microwave and drum dryers are used for special products.

Cheat sheet

Cover the right-hand column and test yourself.

Dryer selection

DryerUse
Tray dryerSmall batches of wet granules
Fluid-bed dryerFast uniform drying of granules
Spray dryerSolutions to free-flowing powders
Vacuum dryerHeat-sensitive or solvent-wet solids
Freeze dryerProteins, vaccines, unstable injectables
Drum dryerThin films of solutions or slurries

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Draw and explain the drying rate curve.

Plotting drying rate against moisture content shows a short warm-up period, then a constant-rate period in which water evaporates from a saturated surface at a rate set by air temperature, humidity and flow. At the critical moisture content the surface dries out and the falling-rate period begins, where moisture must diffuse from inside and the rate drops steadily to zero at the equilibrium moisture content.

Describe the principle and stages of freeze drying.

The product is frozen below its eutectic or glass transition temperature. In primary drying, pressure is lowered and gentle heat is applied so ice sublimes directly to vapour. In secondary drying, the temperature is raised to remove bound water by desorption. The porous cake reconstitutes quickly and suits heat-labile drugs.

Why is a fluid-bed dryer preferred to a tray dryer for granules?

Hot air passes through and suspends every granule, so heat and mass transfer are rapid and uniform. Drying takes minutes rather than hours, migration of soluble components is reduced, and the granules stay free-flowing. It can also be used for granulation and coating.

Now practise the MCQs

This chapter's MCQs sit in the Pharmaceutical Unit Operations topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Lachman and Lieberman's The Theory and Practice of Industrial Pharmacy teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the four parts of the book (processing, dosage form design, dosage forms, and production, quality and regulation); your edition's chapter numbers may differ, so match chapters by title. All Part I chapters