Industrial Pharmacy · Short notes

Pharmaceutical Quality Management System: Short Notes & Cheat Sheet

Pharmaceutical Quality Management System: ICH Q8 to Q10, quality risk management tools, ISO 9001 principles, Six Sigma, Lean, ALCOA+ data integrity, CAPA, change control, product quality review and recalls.

Short notes

Read these before you attempt the topic's MCQs.

ICH Q10 pharmaceutical quality system

MonitoringProcess performance, productqualityCAPACorrective and preventive actionChange managementAssess before changingManagement reviewLeadership oversightKnowledge managementEnablerQuality risk managementEnabler (Q9)PQS (Q10)
Four elements run the system and two enablers support it throughout the product lifecycle.

ICH quality guidelines

  • Q8: pharmaceutical development and Quality by Design. Key terms: quality target product profile (QTPP), critical quality attributes (CQAs), critical process parameters (CPPs) and design space.
  • Q9: quality risk management. Tools include FMEA, FMECA, fault tree analysis, HACCP, HAZOP and risk ranking; risk combines severity and probability (and detectability in FMEA's risk priority number).
  • Q10: the Pharmaceutical Quality System across the product lifecycle: development, technology transfer, commercial manufacturing and discontinuation.
  • Q10's four elements: process performance and product quality monitoring, CAPA, change management, and management review. Its two enablers: knowledge management and quality risk management.
  • Related: Q7 (GMP for active ingredients), Q11 (drug substance development), Q12 (post-approval lifecycle management).

ISO and improvement methods

  • ISO 9001 is a general quality management standard built on seven principles: customer focus, leadership, engagement of people, process approach, improvement, evidence-based decisions and relationship management.
  • Other standards: ISO/IEC 17025 for testing laboratories, ISO 13485 for medical devices, ISO 14001 for environmental management.
  • Six Sigma aims for 3.4 defects per million opportunities, using DMAIC: Define, Measure, Analyse, Improve, Control.
  • Lean removes waste; 5S is Sort, Set in order, Shine, Standardise, Sustain. Kaizen means continuous small improvements.
  • Quality pioneers: Deming (PDCA, 14 points), Juran (quality trilogy, Pareto principle), Crosby (zero defects), Ishikawa (fishbone diagram).

Core QMS processes

  • Deviation handling and CAPA: a corrective action removes the cause of a problem that happened; a preventive action removes the cause of one that might happen.
  • Change control: every change to process, equipment, supplier or document is assessed, approved and recorded before it is made.
  • Annual product quality review (APQR) trends batch data, deviations, complaints, stability and changes for each product.
  • Supplier qualification, self-inspection (internal audit), training records and complaint handling complete the system.
  • Recalls: Class I is a reasonable probability of serious harm or death; Class II, temporary or reversible harm; Class III, unlikely to cause harm.

Data integrity and cost of quality

  • ALCOA+: data must be Attributable, Legible, Contemporaneous, Original and Accurate, plus Complete, Consistent, Enduring and Available.
  • Cost of quality has four parts: prevention (training, validation), appraisal (testing, audits), internal failure (rework, rejects) and external failure (complaints, recalls).
  • Spending on prevention is the cheapest way to cut total quality cost.

Cheat sheet

High-yield facts in one place. Cover the right-hand column and test yourself.

ICH Q guideline → topic

GuidelineTopic
Q1Stability testing
Q2Analytical method validation
Q3Impurities
Q7GMP for APIs
Q8Pharmaceutical development (QbD)
Q9Quality risk management
Q10Pharmaceutical quality system

Quick facts

ItemFact
Six Sigma3.4 defects per million
DMAICDefine, Measure, Analyse, Improve, Control
5SSort, Set, Shine, Standardise, Sustain
Class I recallSerious harm or death likely
FishboneIshikawa · root cause

Memory aids

ALCOA
Attributable, Legible, Contemporaneous, Original, Accurate.
Q8 Design, Q9 Risk, Q10 System
The three linked ICH quality guidelines in order.

Exam traps

  • Q9 is risk management; Q8 is development and QbD.
  • Corrective action fixes a problem that happened; preventive action stops one that has not.
  • ISO 9001 certification does not replace GMP compliance.
  • Class I is the most serious recall class.

Revised? Now test yourself.

Attempt the Pharmaceutical Quality Management System MCQs while the notes are fresh. Anything you get wrong is saved to your incorrect list for the next revision round.

More Industrial Pharmacy notes