Martin · Part VI · Chapter 19

Micromeritics

Particle size and its measurement, particle size distribution, surface area, density, porosity and the flow properties of powders.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Particle size

  • Micromeritics is the science of small particles; particle size affects dissolution, absorption, content uniformity, flow, and the stability of suspensions and emulsions.
  • Size can be expressed as equivalent diameters: projected area (microscopy), Stokes' (sedimentation), volume or sieve diameter.
  • Methods: optical microscopy (about 0.2–100 µm), sieving (above about 45 µm), sedimentation with the Andreasen pipette (Stokes' law), Coulter counter (electrical sensing zone) and laser diffraction.
  • Distributions are often log-normal; geometric mean diameter and geometric standard deviation describe them.

Surface area, density and flow

  • Specific surface area is measured by gas adsorption (BET method) or air permeability; it rises as particles get smaller.
  • True density excludes all voids; granule density excludes inter-particle spaces; bulk density includes all spaces. Tapped density is bulk density after tapping.
  • Porosity = void volume ÷ bulk volume.
  • Carr's compressibility index = (tapped − bulk) ÷ tapped × 100; Hausner ratio = tapped ÷ bulk density. Below 15% and below 1.25 mean good flow.
  • Angle of repose: under 30° excellent, 30–40° acceptable, above 40° poor flow. Glidants (colloidal silica, talc) improve flow.

Cheat sheet

Cover the right-hand column and test yourself.

Flow indices

MeasureGood flow
Angle of reposeBelow 30°
Carr's indexBelow 15%
Hausner ratioBelow 1.25
Flow rate through orificeSteady, without arching

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Define Carr's index and Hausner ratio and state what values indicate good flow.

Carr's index = (tapped density − bulk density) ÷ tapped density × 100; Hausner ratio = tapped density ÷ bulk density. A Carr's index of 15% or less and a Hausner ratio below about 1.25 indicate good flow; above 25% and 1.4 the powder flows poorly.

Describe two methods of particle size analysis and their ranges.

Sieving shakes the powder through a nest of standard sieves and weighs each fraction; it suits particles above about 45 µm. Optical microscopy measures projected diameters of several hundred particles on a slide and suits about 0.2–100 µm. Others are sedimentation (Andreasen pipette), the Coulter counter and laser diffraction.

Why does particle size matter for a poorly soluble drug?

Smaller particles have a larger surface area, so they dissolve faster (Noyes–Whitney), which raises the rate and sometimes the extent of absorption of dissolution-limited drugs such as griseofulvin, digoxin and nitrofurantoin. Very fine powders can, however, flow poorly, aggregate and become charged.

Now practise the MCQs

This chapter's MCQs sit in the Rheology and Micromeritics topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Martin's Physical Pharmacy and Pharmaceutical Sciences teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the sequence of the recent (7th and 8th) editions; your copy's chapter numbers may differ, so match chapters by title. All Part VI chapters