Martin · Part I · Chapter 1

Interpretive Tools: Units, Data and Statistics

SI units and dimensional analysis, significant figures, error and precision, and the statistics used to read pharmaceutical data.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Units and measurement

  • The SI base units used most in pharmacy are the kilogram, metre, second, mole, kelvin and ampere; everything else (newton, pascal, joule, poise) is derived from them.
  • Dimensional analysis checks a calculation by carrying units through it: if the units of the answer are wrong, the method is wrong.
  • Significant figures report how precisely a value was measured; a result should not carry more of them than the least precise measurement used to obtain it.
  • Accuracy is closeness to the true value; precision is closeness of repeated measurements to each other. A method can be precise but inaccurate when a systematic error is present.

Errors and statistics

  • Systematic (determinate) errors bias every result in one direction and can be traced and corrected; random (indeterminate) errors scatter results both ways and are reduced by repeating measurements.
  • The mean describes the centre of data; the standard deviation describes spread; the relative standard deviation (coefficient of variation) is SD ÷ mean × 100 and allows spread to be compared between data sets.
  • In a normal distribution about 68% of values fall within ±1 SD of the mean, 95% within ±2 SD and 99.7% within ±3 SD.
  • Linear regression fits y = mx + c to data such as a calibration line; the correlation coefficient r (or r²) shows how well the straight line describes the points.
  • Logarithmic plots turn exponential processes (first-order decay, drug elimination) into straight lines whose slope gives the rate constant.

Cheat sheet

Cover the right-hand column and test yourself.

Terms to define in one line

TermMeaning
AccuracyCloseness to the true value
PrecisionAgreement between repeated results
Systematic errorOne-direction bias; can be corrected
Random errorScatter both ways; reduced by replicates
RSD (CV)SD ÷ mean × 100
r²Fraction of variation explained by the line

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Distinguish accuracy from precision with a pharmaceutical example.

Accuracy is how close a result is to the true value; precision is how closely repeated results agree. A balance that is not calibrated may give 101.2, 101.3 and 101.2 mg for a 100 mg weight: precise but inaccurate, because a systematic error shifts every reading.

Why is the relative standard deviation more useful than the standard deviation when comparing two assays?

The SD is in the units of the measurement and grows with the size of the values, so it cannot compare a method measuring micrograms with one measuring grams. The RSD expresses spread as a percentage of the mean, so the two can be compared directly.

How would you obtain a first-order rate constant from concentration-time data?

Plot the natural logarithm of concentration against time. A first-order process gives a straight line whose slope is −k; with log base 10 the slope is −k/2.303.

Now practise the MCQs

This chapter's MCQs sit in the Physical Pharmacy Fundamentals topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Martin's Physical Pharmacy and Pharmaceutical Sciences teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the sequence of the recent (7th and 8th) editions; your copy's chapter numbers may differ, so match chapters by title. All Part I chapters