Lachman · Part IV · Chapter 19

Sterilization

Kinetics of microbial death, D and Z values, F0, moist and dry heat, radiation, gas and filtration methods, and biological indicators.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Kinetics

  • Microbial death follows first-order kinetics, so sterility is a probability, not an absolute.
  • D value: time at a given temperature to kill 90% of the population (one log reduction).
  • Z value: temperature rise that reduces the D value tenfold.
  • F0: equivalent minutes at 121 °C delivered to the product; a sterility assurance level of 10⁻⁶ is the usual target.
  • Overkill cycles assume a high count of resistant spores; bioburden-based cycles use the actual count.

Methods

  • Moist heat (autoclave) at 121 °C for 15 minutes or 134 °C for 3 minutes; for aqueous products and equipment; Geobacillus stearothermophilus is the indicator.
  • Dry heat at 160 °C for 2 hours or 170 °C for 1 hour; for glassware, oils and powders; depyrogenation needs about 250 °C.
  • Ionising radiation (gamma from cobalt-60, electron beam) at about 25 kGy; for disposables; Bacillus pumilus is the traditional indicator.
  • Ethylene oxide gas for heat-sensitive devices; it is toxic and residues must be aerated off; Bacillus atrophaeus is the indicator.
  • Filtration through 0.22 µm membranes for heat-labile solutions; Brevundimonas diminuta is the challenge organism.

Cheat sheet

Cover the right-hand column and test yourself.

Biological indicators

MethodIndicator organism
Moist heatGeobacillus stearothermophilus
Dry heatBacillus atrophaeus
Ethylene oxideBacillus atrophaeus
Gamma radiationBacillus pumilus
FiltrationBrevundimonas diminuta
Hydrogen peroxide vapourGeobacillus stearothermophilus

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Define D value, Z value and F0.

D value is the time at a stated temperature needed to reduce a microbial population by 90%. Z value is the rise in temperature needed to reduce the D value by 90%. F0 is the equivalent time in minutes at 121 °C (with Z = 10 °C) delivered by a heat process; an F0 of at least 8–15 minutes is typical for terminal sterilisation.

Why is moist heat more effective than dry heat?

Steam transfers heat quickly by condensing on surfaces and releasing latent heat, and water helps coagulate microbial proteins. Dry heat kills by slower oxidation, so it needs higher temperatures and longer times (160 °C for 2 hours compared with 121 °C for 15 minutes).

Which sterilisation method would you use for an ophthalmic solution of a heat-labile drug?

Sterile filtration through a 0.22 µm membrane into sterile containers under aseptic conditions (Grade A in a Grade B background), with integrity testing of the filter before and after use. Heat or radiation would degrade the drug.

Now practise the MCQs

This chapter's MCQs sit in the Sterile Products topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Lachman and Lieberman's The Theory and Practice of Industrial Pharmacy teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the four parts of the book (processing, dosage form design, dosage forms, and production, quality and regulation); your edition's chapter numbers may differ, so match chapters by title. All Part IV chapters