Aulton · Part I · Chapter 6

Rheology

Viscosity and flow types applied to pharmaceutical products, viscoelasticity, and how rheology affects manufacture, use and stability.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Flow and viscosity

  • Dynamic viscosity is shear stress divided by shear rate (Pa·s); kinematic viscosity is dynamic viscosity divided by density (m²/s, often in centistokes).
  • Newtonian systems have viscosity independent of shear; most pharmaceutical dispersions, gels and creams are non-Newtonian.
  • Shear thinning (pseudoplastic) behaviour lets a gel spread or a suspension pour, then thicken again; it comes from aligning polymer chains or breaking flocs.
  • Plastic flow with a yield stress prevents sedimentation at rest but allows flow once the stress is exceeded.

Viscoelasticity and practice

  • Semisolids are viscoelastic: they behave partly like elastic solids and partly like viscous liquids. Oscillatory testing gives the storage modulus G′ (elastic) and loss modulus G″ (viscous).
  • Creep testing applies a constant stress and follows strain with time to show how a cream holds its shape.
  • Rheology affects pouring, syringeability and injectability, spreading on skin, residence time in the eye and the physical stability of dispersions.
  • Manufacturing (mixing, pumping, filling, coating) depends on flow at the shear rates involved; a measurement must be made at shear rates relevant to the process or use.
  • Temperature changes viscosity; products are tested at storage and use temperatures (25 °C and skin temperature about 32 °C).

Cheat sheet

Cover the right-hand column and test yourself.

Product → useful rheology

ProductDesired behaviour
Oral suspensionThixotropic or plastic: no settling, pours when shaken
Topical gelShear-thinning: spreads, then stays put
Eye dropsMildly viscous: longer contact time
InjectionLow viscosity for syringeability
OintmentHigh yield value: holds shape

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Distinguish dynamic from kinematic viscosity.

Dynamic (absolute) viscosity is the ratio of shear stress to shear rate, in pascal-seconds or poise. Kinematic viscosity is dynamic viscosity divided by the liquid's density, in m²/s or stokes. Capillary viscometers measure kinematic viscosity because flow there is driven by the liquid's own weight.

What do the storage and loss moduli measure?

In oscillatory rheometry, the storage modulus G′ measures elastic energy stored and recovered per cycle (solid-like behaviour); the loss modulus G″ measures energy lost as heat (liquid-like behaviour). A gel with G′ greater than G″ behaves mainly as a soft solid.

Why should rheology be measured at relevant shear rates?

Non-Newtonian products have different viscosities at different shear rates. A suspension at rest experiences very low shear, shaking and pouring intermediate shear, and rubbing on skin or injecting through a fine needle very high shear. A single-point value tells little; the behaviour must be known at the shear of storage, use or manufacture.

Now practise the MCQs

This chapter's MCQs sit in the Rheology and Micromeritics topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Aulton's Pharmaceutics: The Design and Manufacture of Medicines teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the sequence of the 6th edition (2021); some chapters are grouped differently there, so match chapters by title in your copy. All Part I chapters