Aulton · Part VI · Chapter 37

Pulmonary Drug Delivery

Lung anatomy and deposition by particle size, pressurised metered-dose inhalers, dry powder inhalers, nebulisers and inhaler technique.

Short notes

The ideas this chapter teaches, in exam-ready sentences.

Deposition

  • Inhalation delivers drug straight to the airways, giving rapid action with small doses and fewer systemic effects, as with bronchodilators and corticosteroids.
  • Particles deposit by inertial impaction (large particles in the throat and upper airways), sedimentation (1–5 µm in the small airways) and diffusion (below about 0.5 µm in the alveoli).
  • The ideal mass median aerodynamic diameter for lung deposition is about 1–5 µm; particles above about 10 µm hit the throat and are swallowed.
  • Aerodynamic size is measured with cascade impactors (Andersen, Next Generation Impactor).
  • Slow, deep inhalation with a breath-hold favours sedimentation in the small airways.

Devices

  • Pressurised metered-dose inhalers (pMDIs) contain drug in a liquefied propellant (now hydrofluoroalkanes, HFA 134a and 227, which replaced CFCs) with a metering valve; they need coordination of pressing and breathing in.
  • Spacers slow the aerosol, remove large droplets and remove the need for coordination; they suit children and acute attacks.
  • Dry powder inhalers (DPIs) mix micronised drug with lactose carrier; the patient's own fast, deep breath disperses the powder, so they need adequate inspiratory flow.
  • Nebulisers (jet, ultrasonic, vibrating mesh) turn solutions into mist for tidal breathing; they suit high doses, infants and very ill patients.
  • Soft mist inhalers produce a slow-moving aerosol from a solution without propellant.

Cheat sheet

Cover the right-hand column and test yourself.

Particle size → deposition

Aerodynamic diameterMain site
Above 10 µmMouth and throat (swallowed)
5–10 µmUpper airways
1–5 µmBronchioles (ideal)
Below 1 µmAlveoli or exhaled

Questions & answers

Short questions of the kind university papers ask. Answer each one yourself, then open it to compare with the model answer.

Describe the mechanisms of particle deposition in the lung.

Inertial impaction: large, fast particles cannot follow the airflow at bends and hit the walls of the throat and large airways. Sedimentation: particles of about 1–5 µm settle under gravity in the smaller airways, helped by breath-holding. Diffusion: very small particles below about 0.5 µm move by Brownian motion and deposit in the alveoli, though many are exhaled.

Compare pMDIs and DPIs.

pMDIs are compact and work at low inspiratory flow, but need coordination between actuation and inhalation and use propellants. DPIs are breath-actuated, propellant-free and need no coordination, but require a fast, forceful inhalation that young children and patients in severe attacks may not manage, and are sensitive to humidity.

Why are spacers recommended with metered-dose inhalers?

A spacer holds the aerosol so the patient need not coordinate actuation and inhalation. It slows the spray, lets propellant evaporate so droplets become smaller, and traps large particles that would otherwise deposit in the mouth, increasing lung deposition and reducing oral thrush and hoarseness with inhaled corticosteroids.

Now practise the MCQs

This chapter's MCQs sit in the Novel Drug Delivery Systems topic. Anything you get wrong is saved to your incorrect list for the next revision round.

PharmaPrep's own notes on what this chapter of Aulton's Pharmaceutics: The Design and Manufacture of Medicines teaches; no text, tables or figures are reproduced from the book. Chapters are numbered in this guide's own order, which follows the sequence of the 6th edition (2021); some chapters are grouped differently there, so match chapters by title in your copy. All Part VI chapters